Sectors — Car Parks

Car Park LED Lights

Lighting for Surface & Multi-Storey Car Parks

For over 20 years, LED & Power has supplied car park lighting across the UK: floodlights and column-mounted street lights for open sites, tri-proof fittings and bulkheads for covered decks, and bollards for pedestrian routes. Upgrading cuts energy costs by up to 80%.

  • UK 7 Year Warranty
  • Trusted by Operators & Councils
  • Thousands of Installations
  • 4.6 Customer Reviews

Open a Trade Account — Free & Fast

Exclusive trade pricing, dedicated account management and priority stock allocation — set up your account in minutes.

  • Trade pricing & bulk discounts
  • Dedicated account manager
  • Priority stock allocation
  • Fast, free application

Why choose us

Why Choose LED & Power for your Car Park Lighting

With years of experience supplying and designing external lighting across the UK, we help car park owners get the lighting right first time. We specify only proven, premium LED fittings, the best lights in the industry, and put them in the right places using full lux and layout calculations to BS 5489-1 and BS EN 12464-1. Surface car parks, covered decks, ramps and stairwells each need a different approach, and we design for all of them, so you get even light, no dark spots, safer spaces and lower running costs.

  • Free Lighting Design
  • Lux & Layout Calculations
  • Trade Accounts
  • Free Delivery Over £200
Get a Quote

Showing 1–24 of 46 results

Lighting standards

Recommended Lux Levels for Car Parks

The table below shows recommended lighting levels for the main areas of a car park, based on BS 5489-1 for outdoor and road lighting and BS EN 12464-1 for covered and multi-storey parking. Our lighting designers use these values when producing your free photometric design.

Maintained Illuminance (Em) by Application

CIBSE SLL Code for Lighting – recommended values for car park led lights environments

  • Surface Parking Bays (outdoor) 20
  • Covered / Multi-Storey Parking Bays 80
  • Traffic Routes / Drive Lanes 80
  • Entry & Exit Ramps (transition zone, day) 300
  • Pedestrian Routes & Crossings 100
  • Stairwells & Lift Lobbies 100
  • Pay Stations / Ticket Machines 150
  • Perimeter / Security Areas 20–50
0 lux 300 lux max shown
Application area Em lux Uo min UGR max CCT LPD W/m² IP rating
Surface Parking Bays (outdoor) 20 0.25 GR ≤50 4000K ≤2 IP65
Covered / Multi-Storey Parking Bays 80 0.4 UGR ≤25 4000K ≤4 IP65
Traffic Routes / Drive Lanes 80 0.4 UGR ≤25 4000K ≤4 IP65
Entry & Exit Ramps (transition zone, day) 300 0.4 UGR ≤25 4000K site dependent IP65
Pedestrian Routes & Crossings 100 0.4 UGR ≤25 4000K ≤4 IP65
Stairwells & Lift Lobbies 100 0.4 UGR ≤25 4000K ≤5 IP65
Pay Stations / Ticket Machines 150 0.5 UGR ≤22 4000K ≤5 IP65
Perimeter / Security Areas 20–50 0.25 GR ≤50 4000K ≤2 IP65

Source: BS 5489-1 (Code of practice for the design of road lighting) for outdoor areas and BS EN 12464-1 for covered and multi-storey parking. Outdoor areas use the Glare Rating (GR) metric, while covered areas use Unified Glare Rating (UGR). Entry and ramp transition zones are lit brighter by day to let drivers’ eyes adjust, and dim down at night. Security and CCTV areas may call for higher or cooler light. Guidance such as the Safer Parking Scheme (Park Mark) may also apply. Values are a guide only. Speak to our lighting designers for site-specific calculations.

Our Service

Car Park Lighting Design

From the first site survey, our specialists design and deliver a lighting scheme tailored to your car park, open or covered. We balance even coverage, uniformity and glare control with your energy, safety and budget targets, so you get a system that keeps drivers and pedestrians safe and costs less to run.

  • Free, no-obligation lighting design
  • Lux and layout calculations to BS 5489-1 and BS EN 12464-1
  • Transition-zone lighting designed for ramps and entrances
  • Motion sensor, photocell and dimming options
  • Nationwide Supply
  1. 1

    Site Survey & Requirements

    We assess your car park type and layout, column or ceiling heights, existing fittings, pedestrian routes and operating hours.

  2. 2

    Free Lighting Design

    We produce a lux plan with column and fitting positions, wattages and predicted light levels across the site.

  3. 3

    Lux & Layout Calculations

    We confirm maintained illuminance, uniformity and glare control for each area, including ramps and stairwells.

  4. 4

    Clear, Itemised Quote

    A transparent, no-obligation quote with trade pricing applied where relevant.

  5. 5

    Supply & Fast Delivery

    Your fittings picked, packed and delivered across the UK, free over £200.

Common questions

Frequently Asked Questions

Everything you need to know about LED lighting for your car park led lights.

Can LED lighting help reduce running costs?

Yes, significantly. LED car park lighting uses up to 80% less energy than the older SON, metal halide or fluorescent fittings it replaces, and car parks are often lit for long hours or around the clock, so the savings add up quickly. Adding motion sensors, photocells and dimming cuts costs further by lowering output when areas are empty or during daylight. The upfront investment is usually recovered within two to three years.

Do LED car park lights require a lot of maintenance?

No. Quality LED fittings last 50,000 hours or more, often well over a decade, and rarely fail suddenly the way older lamps do. That matters in car parks, where changing fittings on high columns or across multiple decks needs access equipment and can disrupt use. Less frequent replacement means lower maintenance costs and less downtime.

Are LED car park lights environmentally friendly?

Yes. LED uses far less energy, which lowers carbon emissions, and contains no mercury, unlike some older lamp types. Longer life also means less waste from replacements. Combined with sensors that avoid lighting empty areas and optics that limit light spill and sky glow, LED helps car parks run more sustainably and reduces their impact on neighbours and wildlife.

Are LED lights suitable for multi-storey car parks?

Yes, and they are particularly well suited to them. Multi-storey decks benefit from corrosion-resistant, IP-rated fittings such as tri-proof battens and bulkheads that cope with damp, fumes and wash-down cleaning. LED also handles the transition zones at entrances and ramps well, where drivers’ eyes need to adjust between daylight and the darker interior, and works with sensors to keep quieter decks efficient. We design for each level, including stairwells and lift lobbies.

Why is LED lighting suitable for car parks?

LED gives bright, even light that improves safety, wayfinding and CCTV clarity, all of which matter in car parks. It switches on instantly, runs reliably in cold and exposed conditions, and comes in weatherproof and corrosion-resistant housings for both open and covered parking. Combined with low running costs, long life and sensor control, LED is the natural choice for car park operators.

Insights & advice

Latest Blog Stories

Get started

Ready to Upgrade Your Car Park LED Lights?

Tell us about your site and our team will recommend the right fittings, provide a free lighting design and a tailored quote.

Stay Up to Date

Sign up for the latest LED lighting news, product launches and exclusive trade offers.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.